Overview
Alexor PC9155 is a wireless intrusion panel built around compact deployments and fast enrollment workflows.
Official source
- Product page: DSC Alexor PC9155 (ID 53)
- Manual basis: *Alexor Installation Guide v1.1* and *Alexor User Manual v1.1*
Capacity and I/O profile
- Wireless zones: 1 to 32
- Auxiliary output current: 200 mA
- On-board I/O points can be used either as:
- Zone 33 and Zone 34 inputs, or
- Low-current PGM outputs (50 mA)
Enrollment behavior
- Wireless enrollment section: [804]
- First keypad enrollment window is approximately 2 minutes after initial power-up
Signaling options
- Optional communicator modules include TL265, TL265GS, GS2065, and GS2060 family IP/cellular modules.
- For SIA CP-01 installations, minimum equipment is PC9155-433 control panel plus WT5500-433 keypad.
- Optional: WT5500P-433 (prox reader), PT4 prox tags, WT4989 keys, WT4901/WT4911 sirens.
Error Codes
Common trouble patterns
| Symptom | Likely cause | Action |
|---|---|---|
| Keypad does not enroll | Enrollment window expired | Power cycle and re-attempt within first 2 minutes |
| Missing wireless zones | Device not enrolled or out of range | Re-enroll in [804], verify placement and battery |
| PGM not switching | I/O configured as zone instead of PGM | Confirm I/O mode and output mapping |
| AUX overload symptoms | Exceeded 200 mA auxiliary load | Reduce load or add external power strategy |
Fast recovery checklist
- Check power and battery state.
- Confirm keypad enrollment status.
- Validate zone definitions for 1-32 plus I/O mode.
- Re-test communication path after trouble clear.
| Code / display | Meaning | What to do |
|---|---|---|
| Symptom | Likely cause | Action |
| Keypad does not enroll | Enrollment window expired | Power cycle and re-attempt within first 2 minutes |
| Missing wireless zones | Device not enrolled or out of range | Re-enroll in [804], verify placement and battery |
| PGM not switching | I/O configured as zone instead of PGM | Confirm I/O mode and output mapping |
| AUX overload symptoms | Exceeded 200 mA auxiliary load | Reduce load or add external power strategy |
Troubleshooting
Enrollment-first approach
- Start with keypad enrollment immediately after panel power-up.
- If first keypad is missed, restart power and repeat within the initial 2-minute window.
- Use [804] for wireless enrollment verification and cleanup.
Zone and I/O conflicts
- Confirm whether onboard I/O is defined as zones 33/34 or as PGMs.
- Resolve duplicate mappings before zone walk tests.
- Test alarm and restore transitions for every enrolled point.
Power budget checks
- Keep AUX draw within 200 mA.
- For external devices, avoid sourcing power from panel AUX if startup current is unknown.
SIA deployment guardrail
For SIA-oriented deployments, verify minimum equipment set is PC9155-433 with WT5500-433 before dispatch.
Compatible Peripherals
Wireless enrollment ([804]) — typical devices
| Device type | Examples | Notes |
|---|---|---|
| Keypad | WT5500-433 | First keypad within 2-minute power-up window |
| Prox keypad | WT5500P-433 | Prox reader keypad variant |
| Siren | WT4901 indoor, WT4911 outdoor | Enroll after keypad |
| Sensors | WT4xxx contacts, PIR, glass-break | One wireless ID per zone 01–32 |
| Keys | WT4989 wireless keys | Panic/disarm functions per programming |
| Prox tags | PT4 | Enroll to user slots on prox keypad |
Optional communicators
| Module | Path |
|---|---|
| TL265 / TL265GS | IP/cellular reporting |
| GS2060 / GS2065 | Cellular/IP family modules |
SIA CP-01 minimum equipment
PC9155-433 control panel + WT5500-433 keypad — verify before CP-01 labeled installs.
Not compatible
- PowerSeries Keybus PK5500 keypads
- Neo Corbus HS2 keypads
- PowerG-only wireless without 433 MHz Alexor path
- PC5108 / RF5132 PowerSeries modules on Alexor panel
Installation Notes
Suggested install sequence
- Bench power panel and enroll first keypad during the 2-minute startup window.
- Enter [804] and enroll all wireless zones.
- Decide I/O role (zones 33/34 or PGM outputs) and program accordingly.
- Validate communicator path when TL265 or GS2065 is installed.
- Complete full walk test and reporting test before final mounting.
Wireless enrollment sequence ([804])
Enroll in this order: keypad → sirens → sensors → pendants → wireless keys.
- Power panel — AC Power and Ready LEDs flash for ~2 minutes for first keypad enrollment.
- Press any button on the first WT5500 within that window.
- For additional devices, use installer
[804]— enter ESN from device sticker (6-character alphanumeric). - Assign zone 01–32 (one device per zone); accept recommended zone type or scroll options.
- Panel enters individual placement test after each sensor enrollment — verify RF before
[#]to next device. - Run global placement test after all devices are enrolled.
I/O programming ([013] options 1–2)
| Terminal | Zone mode | PGM mode |
|---|---|---|
| I/O-1 | Zone 33 input | PGM output 50 mA |
| I/O-2 | Zone 34 input | PGM output 50 mA |
Cannot use the same point as both zone and PGM simultaneously.
FAQs
How many zones does Alexor support?
Alexor supports wireless zones 1 through 32, plus optional use of I/O points as zones 33 and 34.
Can I use the onboard I/O as outputs?
Yes. The same points can be configured as low-current PGMs at 50 mA each — not simultaneously as zones.
Why did my keypad fail to enroll?
The first keypad must usually be enrolled within about 2 minutes after power-up. If missed, power cycle and repeat.
What order should I enroll wireless devices?
Keypad first (power-up window), then [804]: siren → sensors → pendants → keys.
Which communicator modules are typical?
TL265, TL265GS, GS2060, and GS2065 are optional signaling modules.
What is the AUX current limit?
200 mA total auxiliary — budget sirens, communicators, and external devices accordingly.
Can I add hardwired zones?
Only via onboard I/O as zones 33/34 — not a full hardwired expander like PowerSeries PC5108.