GE Caddx NetworX NX-148E LCD Keypad

GE Caddx · Keypads · Error codes · Troubleshooting · Compatibility · Installation · FAQs · Updated

On this page
  1. Overview
  2. Error Codes
  3. Troubleshooting
  4. Compatible Peripherals
  5. Installation Notes
  6. FAQs

Overview

The NX-148E is the text (LCD) keypad for Caddx NetworX panels: the NX-4, NX-6, NX-8 and NX-8E. Where the LED keypads show troubles as lit zone numbers, the NX-148E spells them out on a 32-character display. That makes it the easiest keypad for reading troubles, zone names and the event log. It has nine status lights and a built-in sounder.

The NX-148E-RF is the same keypad with a 48-zone wireless receiver built in.

Official manual

Interlogix's document library is no longer online. This link opens an archived copy of the original manufacturer PDF on the Internet Archive.

Error Codes

When the display shows Service Required, Type *2 for help, press * 2. Scroll through the messages with the arrow keys, and press # # to leave.

MessageMeaning
Control Loss of timePower was lost completely; set the clock
Control Low BatteryPanel standby battery is low
Control Power troubleMains power to the panel is off
Control Fail to Comm.The panel could not get a message to the central station
Control Phone troubleThe phone line to the panel is not working
Control Siren troubleOpen circuit on the bell or siren wiring
Control Over-currentShort circuit on the panel's power output
Control Ground faultA panel circuit is shorted to ground
Control Box tamperThe cabinet tamper switch opened
Expansion TroubleA module or keypad is not reporting to the panel
Expansion Aux. comm. failA backup communicator (radio, cellular) failed
Expansion RF JammedA wireless receiver is being jammed
Expansion Low Battery / Power troubleAn expansion power supply has a low battery or no mains power
Zone Lost, Press *A wireless zone has stopped reporting; press * to see which
Zone Low Batt, Press *A wireless sensor needs a battery
Zone Tamper, Press *A zone's tamper is open
Zone Trouble, Press *A zone has a fault, usually wiring

The same troubles on an LED keypad appear as numbered lights; see the NetworX service light guide.

Troubleshooting

The function menu

Press * on its own and the display scrolls through the menu. If you know the number, press * followed by it:

KeysFunction
* 0Set keypad tone
* 1Partition master mode (partitioned systems)
* 2Service check
* 3Alarm memory
* 4 4Test (siren/communication, if enabled)
* 4 5Display test
* 4 9Switch to Spanish
* 5Change user PINs
* 6User authority
* 7Reset smoke detectors, zone troubles and tampers
* 9 0Event log
* 9 1Display viewing angle and brightness
* 9 7Set date and time
* ChimeWalk test

Setting the clock

Press * 9 7 and enter the master code. The hour flashes. Change it with the arrow keys, then press * to move on to minutes, day of week, date, month and year.

Reading the event log

Press * 9 0 and the master code. The newest event shows first; use the arrow keys to go back and forward. Each entry shows the event, date, 24-hour time, user or zone number, and partition. An asterisk marks an event that was not reported to the central station. The log is the quickest way to see what happened during an alarm or a trouble.

Display hard to read

Press * 9 1 and the master code. Adjust the viewing angle with the arrow keys, press * for brightness, and * again to finish.

Compatible Peripherals

Installation Notes

  • The keypad connects to the panel's four-wire keypad bus. Each keypad needs its own address so the panel can supervise it. The NX-8E manual recommends partition 1, keypad 1 for the first LCD keypad.
  • After adding or readdressing keypads, enter and exit program mode so the panel enrolls them.
  • Zone descriptions typed in at one LCD keypad can be copied to the others. The NX-8E manual gives the sequence * 9 2, installer code, 1 # #, Exit; the text appears on the other keypads after about 30 seconds.

FAQs

How do I get rid of "Service Required" on an NX-148E?

Press * 2 to read the message, then fix the cause. The most common is Loss of time after a power cut, cleared by setting the clock with * 9 7. Others, like a low battery or a lost wireless zone, clear once the problem is fixed.

Can an NX-148E replace an LED keypad?

Yes. It works on any NetworX panel bus, but give it an address and enter and exit programming so the panel enrolls it.