Overview
The DSC PowerSeries PC1864 is a hardwired burglary control panel from the PC1616/PC1832/PC1864 family (firmware v4.5 and higher in this documentation set). It is aimed at small to mid-size residential and light commercial installs where you need a proven Keybus panel with room to grow through zone expanders, wireless receivers, and IP/cellular communicators—not a touchscreen-all-in-one platform.
At a Glance
| Specification | PC1864 |
|---|---|
| On-board hardwired zones | 8 |
| Maximum hardwired zones | 64 (with up to seven PC5108 modules) |
| Maximum wireless zones | 32 (with RF5132 or RFK55xx receiver) |
| Keypad zone inputs | 11 |
| On-board PGM outputs | 4 (PGM1/3/4: 50 mA; PGM2: 300 mA, supports 2-wire smoke) |
| Maximum PGM outputs | Up to 14 (with PC5208 and PC5204 modules) |
| Keypads supported | Up to 8 on Keybus |
| Partitions | 8 |
| User codes | 95 user codes plus Master code (code 40) |
| Event buffer | 500 events |
| AUX+ bus power | 11.1–12.6 VDC, 700 mA maximum |
| Bell output | 11.1–12.6 VDC residential / 12 VDC commercial, 700 mA, supervised |
| Panel nominal current | 110 mA |
| AC input | 120 VAC / 60 Hz (NA); 16.5 VAC / 40 VA transformer required |
| Battery | Sealed lead-acid or gel; 4 Ah, 7 Ah, or 14 Ah depending on standby requirement |
| Operating environment | 0°C to 49°C (32°F to 120°F), up to 93% RH non-condensing |
What This Panel Does Well
The PC1864 sits at the center of a traditional DSC PowerSeries install: it supervises wired loops and wireless transmitters, drives bell/siren output and PGM relays, reports to a central station over phone, IP, or cellular modules, and supports up to eight partitions for common split residential or small business layouts.
Eight on-board zones cover many installs; adding PC5108 expanders brings the panel to 64 hardwired zones. A RF5132-433 wireless receiver (v5.1+) or RFK55xx-433 keypad with integrated receiver adds up to 32 wireless zones without changing the panel itself.
Programming is done at the keypad with installer code [*, 8, installer code] or remotely through DLS once the user enables the DLS service window. End users arm, disarm, bypass, and read troubles from PK-series LED keypads, PK5500/RFK5500 LCD keypads, or legacy LCD5511/LED5511Z fixed-message keypads.
Before You Service or Replace One
Confirm these details before quoting parts, programming, or a swap:
- Panel family and firmware — Manuals cover PC1616/1832/1864 v4.5+; programming worksheets and feature limits differ by version.
- Region — NA vs EU install manuals and transformer models differ (e.g., PTD1640U-CC for plug-in NA installs).
- Expansion already in place — PC5108 v1 and v2 must not be mixed on the same panel; jumper settings assign zone banks.
- Wireless generation — 433 MHz PowerSeries wireless; CO wireless requires RF5132 v5.1+ or RFK55xx-433 v1.2+ with WS4913 detectors.
- Communicator path — Phone (RJ-31X), T-Link TL-250/TL-300, TL260GS, GS2060, and related modules each have their own wiring and programming sections.
- Listed install type — UL/ULC burglary, fire, and SIA CP-01 false-alarm reduction each impose specific programming defaults (entry/exit limits, EOL types, bell timeout, etc.).
Official Sources
- Product page: DSC PC1864 (ID 3)
- PC1616/PC1832/PC1864 User Manual v4.5 and Installation Manual v4.5 NA/EU — DSC official documentation
Use the official installation manual for wire gauges, resistor values, and programming section numbers; use the user manual for keypad commands and end-user trouble display.
Error Codes
On PC1864 systems, trouble conditions appear at the keypad as a flashing Trouble or System light with a beep every 10 seconds. Press [*, 2] to open the trouble menu; LED keypads show trouble numbers 1–8; LCD keypads scroll descriptions. Press [#] to silence beeps without clearing the underlying fault.
Press [1] when Service Required is shown to view sub-codes 1–8.
Main Trouble Menu
| # | Display | Meaning | Typical cause |
|---|---|---|---|
| 1 | Service Required | One or more internal service faults | See sub-codes below; call your alarm company |
| 2 | Loss of AC Power / AC Trouble | Primary AC missing at panel | Tripped breaker, bad transformer, switched outlet |
| 3 | Telephone Line Fault | Panel cannot see phone line voltage | Line disconnected, RJ-31X wiring, off-hook device |
| 4 | Failure to Communicate (FTC) | Panel could not reach central station | Wrong phone/IP/cellular path, format, or account |
| 5 | Sensor / Zone Fault | Supervisory fault on one or more zones | Open loop, wrong EOL, wireless supervision loss |
| 6 | Sensor / Zone Tamper | Tamper on zone or device | Cover open, broken wire, wireless tamper |
| 7 | Sensor / Zone Low Battery | Low battery on wireless device | Transmitter, wireless key, or keypad battery |
| 8 | Loss of Time & Date | Clock lost after full power loss | Reprogram time/date after AC and battery restored |
Service Required Sub-Codes (Trouble 1 → press 1)
| Sub | Condition | Meaning |
|---|---|---|
| 1 | Low Battery | Main panel battery below ~11.1 VDC; will not clear until ≥12.5 VDC under load |
| 2 | Bell Circuit | Bell output open or short; supervised output fault |
| 3 | General System Trouble | Auxiliary fault (PC5204 output, AUX, printer, T-Link network/receiver/interface, etc.) |
| 4 | System Tamper | Panel or module tamper input open |
| 5 | Module Supervision | Keybus module not communicating (wrong slot, removed module, needs rescan) |
| 6 | RF Jam Detected | Excessive 433 MHz noise at wireless receiver |
| 7 | PC5204 Low Battery | Auxiliary PC5204 supply battery low (<11.5 VDC) |
| 8 | PC5204 AC Failure | No AC at PC5204 transformer input (expect 16–18 VAC) |
Keypad Commands for Troubles
| Action | Command |
|---|---|
| View troubles | [*, 2] |
| Silence trouble beeps | [#] |
| Service Required detail | [*, 2] then [1] when trouble 1 shown |
| Zone fault detail | [*, 2] then [5] — displays faulted zone numbers |
| Zone tamper detail | [*, 2] then [6] |
| Wireless/device low battery | [*, 2] then [7] — cycles zones, keypads, wireless keys, RF delinquency |
| Set time/date after trouble 8 | [*, 8] on PK-series, or [*, 1] time/date in user functions |
Notes for Installers
- New battery: Allow up to one hour of charging before expecting trouble 1-1 to clear.
- Unused bell output: Install a 1000 Ω resistor across Bell+ and Bell− or a bell trouble remains.
- Module supervision reset: Enter programming section
[902], press[*], wait one minute for Keybus rescan; use[903]to identify modules. - Reporting vs keypad: Central station may receive Contact ID or SIA trouble/restoral codes (e.g., AT/EJ for module trouble, YK for phone restore) in addition to keypad display—see Appendix A in the install manual for code mapping.
Source: PC1616/PC1832/PC1864 User Manual v4.5 and Installation Manual v4.5 NA, Trouble Conditions and Appendix D.
| Code / display | Meaning | What to do |
|---|---|---|
| # | Display | Meaning |
| Symptom | Likely cause | |
| 1 | Service Required | One or more internal service faults |
| No keypad display | No Keybus keypad installed or wrong bus wiring | |
| 2 | Loss of AC Power / AC Trouble | Primary AC missing at panel |
| Customer bought "panel" expecting keypad | Order PK5500/RFK5500 separately | |
| 3 | Telephone Line Fault | Panel cannot see phone line voltage |
| Trouble beeping, no text | Install LED/LCD keypad — panel alone may only beep | |
| 4 | Failure to Communicate (FTC) | Panel could not reach central station |
| 5 | Sensor / Zone Fault | Supervisory fault on one or more zones |
| 6 | Sensor / Zone Tamper | Tamper on zone or device |
| 7 | Sensor / Zone Low Battery | Low battery on wireless device |
| 8 | Loss of Time & Date | Clock lost after full power loss |
| Sub | Condition | Meaning |
| 1 | Low Battery | Main panel battery below ~11.1 VDC; will not clear until ≥12.5 VDC under load |
| 2 | Bell Circuit | Bell output open or short; supervised output fault |
| 3 | General System Trouble | Auxiliary fault (PC5204 output, AUX, printer, T-Link network/receiver/interface, etc.) |
| 4 | System Tamper | Panel or module tamper input open |
| 5 | Module Supervision | Keybus module not communicating (wrong slot, removed module, needs rescan) |
| 6 | RF Jam Detected | Excessive 433 MHz noise at wireless receiver |
| 7 | PC5204 Low Battery | Auxiliary PC5204 supply battery low (<11.5 VDC) |
| 8 | PC5204 AC Failure | No AC at PC5204 transformer input (expect 16–18 VAC) |
| Action | Command | |
| View troubles | `[*, 2]` | |
| Silence trouble beeps | `[#]` | |
| Service Required detail | `[*, 2]` then `[1]` when trouble 1 shown | |
| Zone fault detail | `[*, 2]` then `[5]` — displays faulted zone numbers | |
| Zone tamper detail | `[*, 2]` then `[6]` | |
| Wireless/device low battery | `[*, 2]` then `[7]` — cycles zones, keypads, wireless keys, RF delinquency | |
| Set time/date after trouble 8 | `[*, 8]` on PK-series, or `[*, 1]` time/date in user functions |
Troubleshooting
Work through power and supervision first, then communication, then individual zones. Most PC1864 service calls trace back to battery/AC, bell supervision, Keybus wiring, or phone/IP communicator programming—not a failed panel board.
Quick Diagnostic Flow
- Read the keypad —
[*, 2]and note trouble numbers 1–8 (and sub-codes under Service Required). - Verify AC and battery — Transformer 16–18 VAC at panel AC terminals; battery 12.5 VDC minimum under load when charged.
- Check bell supervision — Open bell circuit is trouble 1-2; jumper Bell+/Bell− with 1 kΩ if output unused.
- Inspect Keybus — Red/black/yellow/green continuity, no shielded cable, total wire length within limits.
- Test communication path — Phone voltage at TIP/RING, or IP/cellular module link LEDs and account programming.
- Isolate zone faults — Use
[*, 2], [5]or walk test[901]/ wireless test[904]in installer programming.
Trouble-by-Trouble Fixes
Trouble 1 — Service Required
1-1 Low battery (main panel)
- Measure battery at rest; trouble persists until ≥12.5 VDC under load.
- Verify charging: 13.70–13.80 VDC across battery leads with AC present.
- Check AC: 16–18 VAC at panel transformer input; replace PTD1640-class transformer if low.
- Disconnect battery, remove AC briefly, reconnect battery first then AC. New batteries may need 1 hour to charge before trouble clears.
1-2 Bell circuit
- Disconnect Bell+/Bell−; measure loop—open circuit means break or failed siren.
- If bell output unused, jumper Bell+/Bell− with 1 kΩ (brown/black/red) to clear supervision.
1-3 General system trouble
- PC5204 output 1 unused: Jumper O1 and AUX with 1 kΩ.
- PC5204 output 1 used: Disconnect load and measure for open circuit.
- PC5204 AUX fault: Verify 16–18 VAC at module AC; AUX output should read 13.70–13.80 VDC unloaded.
- Printer offline on PC5400: paper jam, cover, or cable.
- T-Link faults: See TL-150/250/350 installation manual for network, receiver, and interface troubles.
1-4 System tamper
- Short tamper terminal to COM on panel and each Keybus module (PC5100, PC5108, PC5200, PC5204, PC5208, PC5320, PC5400, PC5700) when cover switches are not used.
1-5 Module supervision
- Modules enroll automatically when detected; removed modules or changed keypad slot assignments require a supervision reset: programming
[902], press[*], wait 1 minute for Keybus scan. - Use
[903]to list detected modules; event buffer or PK5500/LCD5500 version screen helps identify which module is in fault. - Confirm keypad assigned to correct slot—wrong slot assignment mimics supervision loss.
1-6 RF jam detected
- Look for external 433 MHz interference sources near RF5132 or RFK receiver.
- Optional: disable RF jam reporting in section
[804]subsection[90]option[7](reduces security—use only when interference is environmental and documented).
1-7 / 1-8 PC5204 battery or AC
- Same voltage checks as main panel but measured at PC5204 battery and AC terminals.
Trouble 2 — AC Failure
- No AC at panel AC input: verify 16–18 VAC; transformer not on switched outlet (required for UL).
- Replace Class 2 16.5 VAC / 40 VA transformer (DSC PTD1640U, PTC1640U, or PTD1640U-CC plug-in).
Trouble 3 — Telephone Line Fault
- Measure TIP/RING at panel: ~50 VDC with phone on-hook, ~5 VDC with phone off-hook.
- Wire line directly to panel TIP/RING through RJ-31X ahead of house phones.
- If voltage is good at demarc but low at panel, check RJ-31X wiring and line seizure.
Trouble 4 — Failure to Communicate
Connect a phone handset to TIP/RING and monitor during test:
| Symptom | Likely fix |
|---|---|
| Continuous dial tone | Reverse TIP and RING |
| Recorded operator message | Wrong programmed phone number; dial number manually; check for leading 9 or blocked 800 |
| No handshake response | Verify communicator format matches central station (Contact ID, SIA, pulse, etc.) |
| Multiple transmits, no handshake | Check account number and reporting codes; Contact ID: use HEX A for digit 0; SIA auto codes: use 0 for zero |
| IP/cellular module | Verify module registration, polling interval, and event routing in communicator programming—not just panel [350]–[376] |
FTC often follows trouble 3 (phone line); fix line supervision first.
Trouble 5 — Zone Fault
Press [5] in trouble menu for zone list.
Fire zones (on-board or expander):
- Fire loops need 5.6 kΩ EOL (green/blue/red).
- Remove leads from Z and COM; measure resistance—open indicates break or missing resistor.
PGM2 as 2-wire smoke:
- Requires 2.2 kΩ EOL (red/red/red) across PGM2 and AUX+ when used as smoke initiating circuit.
Wireless zone fault immediately after enroll:
- Zone number may conflict with PC5108 expander zone or keypad zone input—reassign zone.
- Run module placement test
[904]; relocate transmitter if signal is marginal.
DEOL short:
- Short on double-EOL loop—remove Z/COM leads and measure; reconnect 5.6 kΩ EOL.
Trouble 6 — Zone Tamper
Press [6] for affected zones. Check device cover switches, wireless tamper, and DEOL tamper (infinite resistance = broken wire).
Trouble 7 — Wireless / Device Low Battery
Press [7] repeatedly to cycle zone transmitters, keypads, wireless keys (WS49xx), and RF delinquency conditions. Replace device battery; allow 24 hours before expecting restoral if a reporting delay is programmed.
Trouble 8 — Loss of Time & Date
Full power loss (AC and battery) clears clock. After power restored: [*, 8] on PK-series or user function [*, 6], [1] for time/date entry.
System Will Not Arm
| Symptom | Check |
|---|---|
| Ready light off | Close open zones or bypass [*, 1] while disarmed |
| Trouble beeps | Resolve troubles or, if enabled, use trouble menu acknowledgement to override (logged event) |
| AC/DC inhibit arm enabled | Restore AC/battery or disable inhibit in programming |
| Zone expander supervisory fault | Reset module supervision [902] |
| Auto-arm cancelled | Review event buffer for inhibit reasons |
No Keypad Display / Blank Keypad
- Keybus wiring: red, black, yellow, green to all devices; AUX+ and Keybus red internally linked at panel.
- Total Keybus wire ≤3000 ft (915 m); any single run ≤1000 ft (305 m) from panel.
- Minimum 22 AWG, maximum 18 AWG, twisted pair preferred, no shielded cable.
- If total module current >700 mA, add PC5200 or PC5204 auxiliary supply.
Testing Tools
| Test | Access |
|---|---|
| User system test | [*, 6], [Master code], [4] — bell 2 s, keypad lights, communicator test, battery load |
| Installer walk test | [*, 8], [Installer code], [901] — test each zone; [*, 7], [2] to reset latching smokes after |
| Wireless signal test | [904] + 2-digit wireless zone |
| DLS remote access | User function [*, 6], [5] enables 6-hour DLS window |
Source: Installation Manual v4.5 NA Appendix D; User Manual v4.5 trouble and test sections.
Compatible Peripherals
The PC1864 uses DSC 4-wire Keybus (PowerSeries, not PowerSeries Neo HS2). Compatibility depends on 433 MHz PowerSeries wireless, Keybus firmware version, and regional model—not every DSC catalog part works on this generation panel.
Control Panel Limits (PC1864)
| Resource | Maximum |
|---|---|
| Hardwired zones (on board) | 8 |
| Hardwired zones (with expansion) | 64 (up to seven PC5108 modules) |
| Wireless zones | 32 |
| Keypad zone inputs | 11 |
| Keypads | 8 |
| Partitions | 8 |
| On-board PGM | 2 (PGM1: 50 mA; PGM2: 300 mA, supports 2-wire smoke) |
| Total PGM (with modules) | 14 |
| User codes | 95 + Master |
| Keybus + AUX current | 700 mA (panel supply) |
Keypads
All PowerSeries keypads on Keybus are backward compatible unless noted in module documentation.
| Model | Type | Keybus current (max) | Notes |
|---|---|---|---|
| PK5500 | LCD full-message | 125 mA | Zone bypass scroll, version display, template programming |
| PK5501 | LED 1-zone | 125 mA | |
| PK5508 | LED 8-zone | 125 mA | |
| PK5516 | LED 16-zone | 125 mA | |
| RFK5500 / RFK5501 / RFK5508 / RFK5516 | RFK variants | 135 mA | Integrated 433 MHz receiver option |
| LCD5511 | Fixed-message LCD | 85 mA | Legacy; LCD5500 v2.x or older affects some programming options |
| LED5511Z | 8-zone LED | 100 mA | Legacy fixed LED |
| PKP-LCD / PKP-ICN | Icon keypads | — | SIA CP-01 minimum config keypads |
Requirements: PK55xx or RFK55xx v1.1+ for template programming [899] and some installer prompts. Minimum two keypads for UL Home Health Care listed configs.
Zone Expansion and Hardwired Interfaces
| Module | Function | Keybus current | PC1864 notes |
|---|---|---|---|
| PC5108 | 8-zone expander | 30 mA | Expander modules → 16 total hardwired zones; set J1–J3 jumpers for zone bank |
| PC5100 | 2-wire smoke interface | 40 mA + devices (170 mA max) | Smoke power and reset |
| PC5700 | Large zone expander | — | Enrolls as two Keybus modules |
Important: Do not mix PC5108 v1.0 and PC5108 v2 on the same panel. PC5108 v1 supports zones 1–32 only.
Power Supplies and PGM Modules
| Module | Function | Keybus current |
|---|---|---|
| PC5200 | Auxiliary power supply | 20 mA |
| PC5204 | Power supply + 4 PGM (500 mA each) | 30 mA |
| PC5208 | 8 low-current PGM (50 mA each) | 50 mA |
| PC5320 | Output module | See install sheet |
Use PC5200/PC5204 when Keybus devices exceed 700 mA panel budget.
Wireless (433 MHz PowerSeries)
| Module | Function | Keybus current | Requirements |
|---|---|---|---|
| RF5132-433 | Wireless receiver | 125 mA | v5.1+ for wireless CO |
| RF5108-433 | 8-zone wireless receiver | 125 mA | |
| RFK55xx-433 | Keypad with receiver | 135 mA | v1.2+ for wireless CO |
Wireless CO: Use WS4913 transmitters only with RF5132 v5.1+ or RFK55xx-433 v1.2+.
Wireless keys: WS4939 and related WS49xx series; arm/disarm squawk programming in [014] when used.
Supported hardwired CO detectors (examples): Potter CO-12/24, Quantum 12-24SIR, NAPCO FW-CO12/FW-CO1224, System Sensor CO1224.
Communicators and Reporting
| Module | Path | Keybus current (approx.) |
|---|---|---|
| TL-250 / TL-300 | IP / intranet to T-Link receivers | 275 / 350 mA |
| TL260GS / TL265GS | Ethernet + GPRS | 100 mA |
| TL260 / TL260GS-SM | Ethernet variants | 100–120 mA |
| GS2060 / GS2065 | GPRS/GSM | 65 mA |
| GS2060-SM | GPRS only | 90 mA |
| Escort5580TC | Telephone interface | 130 mA |
| On-board phone dialer | POTS via RJ-31X | — |
Note: T-Link TL-150 is not UL/ULC listed. Verify central station receiver compatibility (Contact ID, SIA, pulse formats—Appendix F in install manual).
Serial / Automation / Access
| Module | Function |
|---|---|
| PC5400 | Serial/printer interface (general system trouble source if offline) |
| IT-100 / Envisalink (third-party) | Often used on this generation—verify firmware; not in DSC v4.5 manual table |
Cabinets and Transformers
| Part | Use |
|---|---|
| PC5003C | Standard residential cabinet (222 × 298 × 78 mm) |
| PC500C | Residential burglary |
| PC4050CAR | UL commercial burglary |
| CMC-1 | Attack-resistant / UL local central station |
| SAE 14 / 21 / 28 / 42 | Larger commercial cabinets |
| PTD1640U / PTC1640U / PTD1640U-CC | 16.5 VAC 40 VA transformers |
| PTD1640 | Canadian installs |
Bell / Siren Output
Panel bell output: 700 mA continuous, supervised. Compatible with DSC SD-series and other 12 V sounders within current limit; use external relay for high-current sirens.
Not Compatible / Wrong Generation
- PowerSeries Neo (HS2xxx) keypads, receivers, and modules—different platform.
- PowerG / Qolsys / IQ devices—different wireless ecosystem.
- ITv2 modules without verifying specific PowerSeries v4.x support documents.
- Mixing PC5108 v1 and v2 expanders on one panel.
When replacing a panel, match Keybus modules, wireless frequency (433 MHz), communicator type, and programming version before promising a drop-in swap.
Source: Installation Manual v4.5 NA compatible devices table and wiring sections; User Manual v4.5 keypad list.
Installation Notes
These notes summarize critical install steps for the PC1864 from the NA Installation Manual v4.5. Always follow the full DSC installation manual for programming section numbers, UL/ULC listed configurations, and regional differences (NA vs EU variants).
Pre-Install Checklist
- Confirm cabinet size for planned modules (PC5003C residential, PC500C, PC4050CAR commercial UL, CMC-1 attack-resistant).
- Plan zone count: 6 on board, up to 16 with one PC5108; up to 32 wireless with receiver.
- Plan Keybus devices: max 8 keypads, current budget 700 mA from panel AUX+ (add PC5200/PC5204 if exceeded).
- Verify two keypads minimum for UL Home Health Care (PK5500, PK5501, PK5508, or PK5516).
- Do not apply AC power until all wiring is verified.
Mounting and Power
- Mount modules on cabinet stand-offs first, then mount cabinet in dry location with unswitched AC (UL requirement).
- Connect 16.5 VAC / 40 VA Class 2 transformer (DSC PTD1640U, PTC1640U, or PTD1640U-CC plug-in). Primary: 120 VAC / 60 Hz / 0.33 A. Never on a switch-controlled outlet for listed installs.
- Connect sealed lead-acid or gel battery before applying AC:
| Battery | Standby (approx.) |
|---|---|
| 4 Ah | 700 mA load — meets 4 hr UL burglary |
| 7 Ah | 180 mA load — meets 24 hr fire/health care |
| 14 Ah | 470 mA load — extended standby |
- Charging current: 400 mA. Replace battery every 3–5 years.
- Maintain 1/4 in (6.4 mm) separation between power-limited and non-power-limited wiring (battery leads are not power limited).
Keybus Wiring
Four-wire Keybus (RED, BLK, YEL, GRN) connects panel to all keypads and modules:
- 22 AWG minimum, 18 AWG maximum, twisted pair preferred.
- Do not use shielded wire.
- Home run, series, or T-tap wiring allowed if:
- No module farther than 1000 ft (305 m) from panel.
- Total Keybus wire ≤3000 ft (915 m).
- AUX+ and Keybus RED are internally connected at the panel—do not double-feed.
Keybus Current Budget (partial list)
| Device | Current |
|---|---|
| PK55xx keypad | 125 mA max |
| RFK55xx keypad | 135 mA max |
| LCD5511 fixed LCD | 85 mA max |
| LED5511Z 8-zone LED | 100 mA max |
| RF5132-433 receiver | 125 mA |
| PC5108 zone expander | 30 mA |
| PC5204 power supply / PGM | 30 mA |
| TL-250 / TL-300 communicator | 275 / 350 mA |
If total draw exceeds 700 mA, add PC5200 or PC5204 auxiliary power.
Zone Wiring
- Normally open loops allowed; UL listed installs require SEOL or DEOL only.
- Wire: 22–18 AWG non-shielded; loop resistance ≤100 Ω.
- Programming:
[001]–[004]zone definitions;[013]opt 1 NC/EOL; opt 2 SEOL/DEOL;[101]–[108]opt 14–16 for on-board zones 1–8 (PC1864).
EOL Resistor Values (DEOL)
| State | Resistance |
|---|---|
| Fault (short) | 0 Ω |
| Secure (closed) | 5.6 kΩ |
| Tamper (open wire) | infinite |
| Violated (open contact) | 11.2 kΩ |
Fire zones use 5.6 kΩ (green/blue/red). Burglary loops typically 5.6 kΩ SEOL or DEOL per programming.
PGM2 as 2-wire smoke: Style B supervised; 2.2 kΩ SEOL; max loop 24 Ω; PGM2 rated 300 mA.
Bell / Siren Output
- 700 mA @ 11.1–12.6 VDC residential; supervised by 2 A PTC.
- If output unused, install 1000 Ω across Bell+ and Bell− to prevent bell circuit trouble.
- NFPA 72 Temporal Three: enable
[013]option 8 for fire signal pattern.
PGM Outputs (PC1864)
- PGM1: 50 mA sink to ground; device + to AUX+, − to PGM.
- PGM2: 300 mA; can initiate 2-wire smoke with proper EOL.
- Higher current: drive external relay from PGM.
Expand to 14 PGM total with PC5208 (8 low-current PGM) and PC5204 (4 × 500 mA outputs).
Telephone / Communicator
- Wire TIP, RING, T-1, R-1 to RJ-31X in series ahead of all house phones (26 AWG minimum).
- Program format in
[350]; call direction[351]–[376]. - IP/cellular: mount TL-250, TL-300, TL260GS, GS2060, etc. per module manual; panel programming references communicator sections in install guide Appendix F.
Wireless
- RF5132-433 v5.1+ or RFK55xx-433 v1.2+ for wireless CO (WS4913 only).
- Hardwired CO models approved: Potter CO-12/24, Quantum 12-24SIR, NAPCO FW-CO12/1224, System Sensor CO1224.
- Enroll wireless zones in installer programming; test with
[904]placement test.
Grounding
- Connect cabinet ground lug per local code and manual grounding diagram—required for reliable supervision and listed installs.
Initial Power-Up Sequence
- Battery connected with correct polarity (red +, black −).
- Apply AC; allow battery charge.
- Loss of clock trouble is normal after first power or full power loss—set time/date:
[*, 8]on PK-series or[*, 1]in user functions. - Enter installer programming
[*, 8, installer code]; program[001]–[006]basics (labels, delays, account, phone). - Enroll modules; if supervision faults appear, run
[902]rescan. - Walk test zones
[901]; reset latching smokes with[*, 7, 2]when complete. - Verify central station receives test signals with correct account and format.
UL / SIA CP-01 Highlights (when applicable)
- All burglary zones: SEOL or DEOL (
[013]opt 1 OFF). - Entry delay ≤60 s, exit delay ≤120 s (
[005]). - Minimum bell timeout: 4 min burglary; 5 min ULC residential fire / UL health care; 15 min UL commercial burglary.
- Bypass requires code (
[015]opt 5 ON); trouble beeps ON ([023]opt 7 ON). - SIA minimum system: PC1864 + PK5500/PK5501/PK5508/PK5516/PKP-LCD/PKP-ICN.
Programming Entry Quick Reference
| Task | Command / section |
|---|---|
| Installer programming | [*, 8, installer code] |
| Quick setup wizard | [*, 8], [899] template code (PK55xx v1.1+) |
| Default installer code | [9999] or [5555] until changed in [006] |
| Module supervision reset | [902], press [*], wait 1 min |
| Identify Keybus modules | [903] |
| Walk test | [901] |
| Wireless placement test | [904] + zone |
Source: PC1616/PC1832/PC1864 Installation Manual v4.5 NA (DSC official documentation).
FAQs
Is the PC1864 still a supported DSC product?
Yes. DSC continues to host PC1616 documentation on the official product page and CMS download library. DSC hosts User Manual v4.5 and Installation Manual v4.5 (NA and EU). Newer revisions (v4.6, v4.7) may apply—check revision before applying region-specific listed-install rules.
How many zones does the PC1864 actually have?
Eight hardwired zones on the board. With PC5108 expanders, the panel supports up to 64 hardwired zones. Up to 32 wireless zones are available with an RF5132-433 or RFK55xx-433 receiver. Keypads can also contribute zone inputs (11 keypad zones supported system-wide).
What is the difference between PC1616, PC1832, and PC1864?
All three share the same manual family and Keybus peripherals. The PC1616 is the smallest: 6 on-board zones, 2 partitions, 48 user codes, 2 on-board PGM outputs. The PC1832 adds zones and partitions; the PC1864 is the largest in the line. Programming section numbers are shared—verify the model-specific limits in the install manual feature table before assigning zones or partitions.
Why do my manuals cover three models?
DSC publishes combined installation and user manuals for the PC1616/PC1832/PC1864 platform. Always confirm which limits apply to PC1616 specifically (zone count, partitions, user codes, PGM count).
Can I use PowerSeries Neo keypads or PowerG sensors?
No. The PC1616 is classic PowerSeries with 433 MHz DSC wireless and 4-wire Keybus. Neo HS2 keypads, PowerG receivers, and IQ ecosystem devices are a different product line.
How do I view trouble conditions?
Press **[*, 2] while disarmed. The trouble light flashes and the keypad shows trouble numbers 1–8. Press [#] to silence beeping. For Service Required, press [1]** to see sub-codes (low battery, bell fault, module supervision, etc.). See the error codes section on this product listing for the full table.
The panel shows Loss of Time & Date. Is it broken?
Not necessarily. This trouble appears after complete power loss (AC and battery removed or depleted). Restore power, wait for battery charging if needed, then reprogram time and date with **[*, 8]** on PK-series keypads or through user functions.
Why is there a bell circuit trouble with no siren connected?
The bell output is supervised. If you are not using Bell+/Bell−, install a 1000 Ω resistor across the terminals. Otherwise the panel reports trouble 1-2 indefinitely.
How many keypads can I install?
Up to eight keypads on Keybus. Total current for all modules and keypads must stay within 700 mA from the panel AUX+ output unless you add a PC5200 or PC5204 auxiliary supply.
Can one PC1616 serve multiple areas or tenants?
Yes, partially. The PC1616 supports 2 partitions with separate arming and user code assignment. It does not support eight partitions like the PC1864. Assign partition access in user code programming [*, 5, master, 98, user].
What communicator options work with the PC1616?
Common options include on-board phone dialer (RJ-31X line seizure), T-Link TL-250/TL-300 IP communicators, TL260GS Ethernet/cellular combinations, and GS2060 cellular modules—all connect via Keybus with current listed in the install manual. Programming format and account numbers are in installer sections [311]–[381] and Appendix F.
Why does the panel fail to communicate even though the phone works?
Failure to communicate (trouble 4) is not the same as a dead phone line. Check programmed phone numbers, communicator format (Contact ID, SIA, pulse), account number, handshake compatibility with the central station, and whether telephone line trouble (3) is also present. IP/cellular paths need module link status and receiver enrollment—not just panel programming.
How do I reset module supervision after swapping a PC5108 or keypad?
Enter installer programming and run section [902], press **[*], and wait one minute for the Keybus rescan. Use [903]** to verify detected modules. Wrong keypad slot assignment also causes supervision faults.
What battery size does the PC1616 need?
Use sealed lead-acid or gel batteries. Size depends on standby requirement: 4 Ah for typical UL burglary (4 hr), 7 Ah or 14 Ah for 24 hr fire or health care listed installs. Charging is 400 mA; replace every 3–5 years.
Can I replace a PC1616 with a newer panel and keep everything?
Sometimes, but not automatically. Reuse depends on matching Keybus modules, 433 MHz wireless enrollments, communicator type, and programming migration (DLS backup/restore or reprogram). Neo panels require different peripherals. Survey expanders, receivers, and communicators before quoting a upgrade.
Where is the official documentation?
DSC hosts User Manual v4.5 and Installation Manual v4.5 (NA and EU) on the official PC1616 product page. Newer revisions (v4.6, v4.7) may apply for your region.